S1-33103010000 - How to Replace a York Furnace Control Board

This guide outlines the control-board replacement sequence described for a York furnace. The supplied instructions do not identify a furnace model, so confirm the replacement board fits your exact unit before beginning.

Part number: S1-33103010000 · Brand: York · Model: Not specified

A furnace control board handles electrical connections and furnace operation. If you are not qualified to work on furnace wiring, have a trained technician perform this repair.

Tools and supplies

  • Small pliers

Before you begin

  • Turn off power to the furnace before opening the blower compartment or handling the control board. Do not restore power until the panel is secured.
  • Furnaces contain hazardous electrical circuits. If you are unsure how to safely disconnect power or handle the wiring, contact a qualified technician.
  • The part number provided is S1-33103010000; verify compatibility with the furnace's exact model before installation.

Step-by-step instructions

  1. Disconnect power and open the blower compartment — Turn off power to the furnace. Rotate the knobs securing the blower-chamber panel, then pull the panel away to access the control board.
  2. Release the existing control board — Use small pliers to squeeze the tabs on the board's mounting pins. Release the pins and move the old board aside, keeping its wires connected for transfer.
  3. Mount the replacement board and transfer wiring — Position the new board on the mounting plate and snap its mounting pins into place. Move each wire from the old board to the corresponding connection on the replacement board. Remove terminal covers from the new board if needed to make the connections.
  4. Close the compartment and restore power — Reposition the blower-chamber panel and rotate its knobs to secure it. Restore power to the furnace only after the panel is in place.

After the repair

Confirm that the furnace operates properly after power is restored. If it does not start or operate normally, turn off power and contact a qualified technician.