The heat pump must be removed from its wall sleeve to access the board and sensors. Have an assistant help with moving the unit. Follow the sequence below, keeping track of each screw, connector, sensor route, and cover as it is removed.
Tools and supplies
- #2 Phillips screwdriver
- Wire cutters
- Zip ties
- Power drill with 5/16-inch socket
- Towel or blanket
Before you begin
- Turn the unit off and disconnect its power supply before beginning. Do not work on the unit while it is connected to power.
- The unit is heavy and must be pulled from its wall sleeve. Have an assistant support and move it; set it on a stable towel or blanket.
- If you are not qualified to work around the unit’s electrical wiring, have a qualified appliance technician perform the repair. Do not attempt live electrical testing.
Step-by-step instructions
- 1. Remove the unit from the wall sleeve — Turn off the unit and disconnect power. Pull the bottom of the front panel outward to release it from its tabs, then lift the panel up and off. If present, disconnect the thermostat and energy-management wire connectors. Remove the four wall-sleeve mounting screws using the drill and 5/16-inch socket. With an assistant, slide the unit out and set it on a towel or blanket.
- 2. Open the electrical and control-box covers — Remove the screw holding the control panel and detach the panel. Remove the lower-right screw from the junction-box cover, then remove the three screws holding the junction box. Pull back the cover enough to detach the box from the power cord, and disconnect the power-cord wire connector. Remove the six screws holding the control box’s side access cover and take the cover off. Remove the four screws from the left access cover and the five screws from the middle access cover.
- 3. Disconnect and release the old board and sensors — Disconnect the relay-board and transformer connectors from the main control board. Remove the two screws securing the board to its mounting plate and detach the board. Cut the zip tie bundling the wires. Release the display-board connector locks and disconnect both connectors. Cut the ties securing the ambient-temperature and indoor-coil sensor wires; unclip the ambient sensor from its brackets and remove the indoor-coil sensor from its sleeve. Cut the ties securing the outdoor-coil sensor wire, release it from its retainer, and remove the sensor from its sleeve. Remove the screw holding the wire cover and pull the outdoor-coil sensor wire through the access hole.
- 4. Remove the blower cover and discharge-air sensor — Remove the six screws securing the discharge-air screen and set the screen aside. Remove the screws holding the two fan-housing support brackets, then remove the four remaining screws securing the indoor-blower cover. Cut the tie holding the discharge-air temperature sensor and remove the sensor from its sleeve. The old board and sensors can now be removed.
- 5. Position the replacement board and route the sensor wires — Feed the sensor wires and display-board connectors through the hole in the control box’s side panel. Route the discharge-air sensor into the indoor-blower housing and the outdoor-coil sensor through its wire-access hole. Insert the discharge-air sensor into its sleeve and secure its wire with a new zip tie.
- 6. Refit the blower components and sensors — Realign the blower-housing baffle and reposition the indoor-blower cover; reinstall its screws. Refit both fan-housing support brackets and secure them with their screws. Reposition the discharge-air screen and reinstall its six screws. Insert the outdoor-coil sensor into its sleeve, hook its wire into the retainer, and secure the wire with a new zip tie. Refit the wire cover and its screw. Insert the indoor-coil sensor into its sleeve. Route the ambient sensor through the right mounting bracket and snap it into the middle bracket. Secure the sensor wires with new zip ties.
- 7. Install and reconnect the control board — Reconnect both display-board connectors and slide their locks into place. Bundle the wires with a new zip tie. Align the replacement main control board on its mounting plate and install the two screws. Reconnect the relay-board and transformer connectors to the main board.
- 8. Close the control box and junction box — Reinstall the middle access cover with its five screws, the left access cover with its screws, and the side access cover with its six screws. Reconnect the power-cord wire connector. Reposition the junction box and reinstall its three screws; secure the junction-box cover with the lower-right screw. Refit the control panel and its screw.
- 9. Reinstall the unit and restore power — With an assistant, slide the unit into the wall sleeve until its seal rests against the front of the sleeve. Reinstall the four mounting screws without overtightening. Reconnect the thermostat and energy-management connectors if they were present. Align the front-panel tabs over the top rail, then push the panel’s bottom inward until it snaps into place. Restore power.
After the repair
Check that the front panel is seated and the unit is secured in the sleeve. Restore power and confirm the heat pump starts and operates. The source procedure does not specify additional diagnostic tests or performance measurements.