Free shipping & taxes included on all orders
Step-by-step repair guide

30132161 - How to Replace a Carrier/Gree ETAC Heat Pump Relay and Power Control Board

This procedure replaces the relay and power control board by opening the unit, documenting and transferring its wiring, fitting the replacement board, and reassembling the covers and panels.

Part number: 30132161 · Brand: Carrier/Gree · Model: ETAC heat pump; exact model number not specified

The procedure below follows the supplied instructions for a Carrier/Gree ETAC heat pump. Confirm the replacement board is correct for your exact unit before starting; the part number alone does not establish fitment.

Tools and supplies

  • #1 Phillips screwdriver
  • #2 Phillips screwdriver
  • Short #2 Phillips screwdriver
  • Wire cutters
  • Zip ties
  • Needle-nose pliers

Before you begin

  • Turn the unit off and disconnect its power supply before opening it. Do not restore power while wiring or covers are being worked on.
  • This repair involves power wiring and a compressor capacitor. If you are not qualified to work safely around these components, have a qualified appliance or HVAC technician do the repair.
  • Do not rely on memory when transferring numerous wires. Record their original positions and orientation before disconnecting them.

Step-by-step instructions

  1. 1. Remove the front panel and control panel — With the unit off and power disconnected, pull the bottom of the front panel outward to release its tabs, then lift the panel up and away. Remove the screw securing the control panel with a #2 Phillips screwdriver, then detach the control panel.
  2. 2. Move the junction box and disconnect the power cord connector — Remove the lower-right screw from the junction box cover, then remove the three screws holding the junction box. Pull the cover back to free the box from the power cord, and disconnect the power cord wire connector.
  3. 3. Open the control-box access covers — Remove the six screws securing the side access cover and take the cover off. Remove the four screws securing the left access cover, then remove the five screws securing the middle access cover.
  4. 4. Disconnect wiring and clear the middle cover — If present, disconnect the wall thermostat and energy management wire connectors. Disconnect the relay-board and transformer connectors from the main control board so the middle access cover can be moved out of the way.
  5. 5. Move the capacitor and release the old board — Using the short #2 Phillips screwdriver, remove the screw from the compressor capacitor mounting strap and move the capacitor aside. Use a #1 Phillips screwdriver to remove the two screws holding the relay and power control board to its mounting plate. Cut the existing wire bundle tie, then record the orientation and terminal locations of all 18 board wires. Lift insulators or release connector locks as needed; needle-nose pliers can be used to depress applicable locking tabs. Disconnect all 18 wires, then disconnect the two power wires from their terminal blocks and remove the old board.
  6. 6. Transfer the wires and secure the replacement board — Feed each of the two power wires through its corresponding current sensor on the replacement board, then reconnect the wires to the terminal blocks. Reconnect all 18 wires to the matching terminals using your recorded positions. Refit connector locks and slide the insulators back over the terminals where applicable. Position the board on the mounting plate and secure it with the two screws. Bundle the wires with a new zip tie.
  7. 7. Refit the capacitor and reconnect the control wiring — Return the capacitor to its mounting strap and secure it with the screw. Reconnect the relay-board and transformer connectors to the main control board. Align the middle access cover and secure it with its five screws; reconnect the thermostat and energy management connectors if applicable. Reposition the left access cover and reinstall its screws.
  8. 8. Close the remaining covers and panels — Align the side access cover and secure it with its six screws. Reconnect the power cord wire connector, reposition the junction box, and reinstall its three screws and cover screw. Reattach the control panel and secure it with its screw. Align the front-panel tabs over the top rail, then press the bottom inward until it snaps into place.
  9. 9. Restore power and check operation — After confirming the wiring is connected and the covers and panels are secured, restore power to the unit. Check that the ETAC heat pump operates as expected. If it does not, disconnect power again and contact a qualified technician.

After the repair

The supplied procedure calls for restoring power after reassembly and checking that the ETAC heat pump is ready for use. If the unit does not operate as expected, disconnect power and seek qualified service.

Repair safety: Disconnect power before working on internal parts. Follow the service instructions for your exact appliance model. Contact a qualified technician for hazardous electrical or gas-system work.