Product Description
The 50A65-474 furnace blower control circuit board is a replacement control board for compatible Trane, White-Rodgers, and American Standard furnace systems. It is designed for single-stage integrated furnace HSI control applications with 80V ignition and includes igniter fault detection, automatic malfunction shutdown, reverse-polarity protection, LED fault indication, and system lockout functionality. The board operates with a 25 VAC, 50/60 Hz input and has a maximum 0.45 amp input current.
Verified replacement and cross-reference numbers include 50A65-5165, 50A65-475, 50A65-476, CNT05164, CNT3076, CNT03076, CNT05165, CNT03798, D341213P01, D341396P01, D341396P03, D341396P04, and D341396P05. Before ordering, compare the number on your existing board, connectors, board layout, and complete furnace model to confirm compatibility.
Product Specifications
BrandSI-CBD-0014
Item Weight9.1 ounces
Package Dimensions7.87 x 5.12 x 1.57 inches
ColorGREEN
Explicit OE/OEM Part Numbers50A65-475
Input Voltage25 VAC, 50/60 Hz
Maximum Input Current0.45 amp at 25 VAC
Operating Temperature Range-40° to 175°F (-40° to 80°C)
Ignition Application80V ignition
Board ColorGreen
FunctionsIgniter fault detection; automatic malfunction shutdown; reverse polarity protection; LED fault indication; intelligent system lockout
Appliance TypeOther
Replacement Part Numbers50A65-475, 50A65-5165, 50A65-476, CNT05164, CNT3076, CNT03076, CNT05165, CNT03798, D341213P01, D341396P01, D341396P03, D341396P04, D341396P05
Compatible BrandsTrane, White-Rodgers, and American Standard