The control panel has no display or functionality after an electrical surge or damage to the home's incoming power lines.

Part number: WPW10201915Appliance brand: Maytag3 customer repair reports

Common Symptoms

The range control panel is blank or has no functionality, particularly after an electrical surge or power-line problem.

What to Check

Note whether the failure began immediately after the electrical event and whether the panel is completely unresponsive. The experiences associated with this part included removing the oven from a cabinet to access the control, so access may be more involved than a simple panel opening.

Have the range and its power supply diagnosed for your exact model before ordering a replacement. A surge-related failure does not by itself confirm which component was damaged.

When the Control Board May Be Involved

The control stopped working after electrical trouble in these repairs, and the board is the part associated with them. That history makes the board one possibility, not a definite diagnosis. Confirm the model compatibility and diagnosis before replacing it.

Safety

Disconnect power before inspecting internal components. Use a qualified technician for electrical diagnosis or if the oven must be removed from a cabinet.

Possible Causes

An electrical surge was identified as the cause in one repair experience, and another described the control stopping after power-line trouble. These accounts do not establish that the control board is always responsible; a qualified technician should check the range and its power supply before a part is replaced.

What to Check

Note whether the control panel is completely blank and whether the problem began after a surge or power-line event. Have the range's power supply and controls diagnosed for the specific model. Do not remove an installed oven from a cabinet unless you can do so safely; this may require a technician.

Repair note: These troubleshooting details summarize reported repair experiences. Symptoms can have more than one cause. Disconnect power before inspecting electrical components, and use a qualified technician when a repair involves hazardous voltage or uncertain wiring.