Common Symptoms
The range control may go blank or flicker, or both the oven and surface elements may stop heating. When several functions fail at once, check the range’s electrical supply before assuming the control board has failed.
What to Check
- Check the breaker for the range. A tripped or damaged breaker can interrupt power.
- If the oven and cooktop stopped working together, have the outlet and 240-volt supply checked by a qualified technician. One repair found a dead leg at the outlet caused by a failed breaker, and the original control board was still usable.
- If the control is blank, or the range stopped working after a lightning strike, further diagnosis may be needed to determine whether the board was damaged.
When the Control Board May Be Involved
A blank control or lightning-related failure can make the control board a possibility, but the symptoms alone do not confirm it. Some repairs involved replacing the board; in another case, checking the electrical supply revealed the actual problem. Consider WB27X22940 only after the range’s power supply and model-specific diagnosis support replacing the board.
Before Replacing the Board
Confirm that WB27X22940 fits the complete model number on your range. Disconnect power before inspecting internal components, and use a qualified technician for electrical diagnosis or any work involving the range’s 240-volt supply.
Possible Causes
Possible causes include an interrupted or faulty electrical supply or a failed range control board. One repair found a failed breaker and a dead leg at the 240-volt outlet; replacing the board was not necessary in that case. Other repair experiences describe replacing the board after a blank control or lightning-related damage, but those experiences do not establish that the board is the cause of every similar symptom.
What to Check
Check whether the range has power and whether a breaker has tripped. If the oven and cooktop stopped working together, have the 240-volt supply and breaker checked before replacing the board. A blank control or known lightning damage may warrant further model-specific diagnosis. Disconnect power before inspecting internal components; use a qualified technician for electrical diagnosis.