Common Symptoms
The refrigerator compartment is not cooling properly. The evaporator fan may feel sticky when turned by hand, and an Er rF indication may be relevant on models whose service manual uses it in fan troubleshooting.
What to Check
Use the service manual for the exact refrigerator model to identify the correct fan checks and any test-mode procedure. In one repair, the fan was found to stick, and a technician measured fan voltage outside the manual’s stated range. That reading and range are specific to that repair and should not be applied to other models.
Disconnect power before inspecting internal components. Electrical measurements and service-mode diagnosis should be handled by a qualified technician.
When the Control Board May Be Involved
A problem with the fan or its power circuit can contribute to poor refrigerator cooling. In the repair associated with this part, both the evaporator fan and the EBR78940616 control board were replaced, and the problem was corrected. Because the fan was also sticking, this does not show that the board alone caused the symptom.
Before Replacing the Board
Confirm the fan’s condition and follow the model-specific service procedure before ordering a control board. A refrigerator that is not cooling properly can have more than one cause, so the board should be considered only after appropriate diagnosis.
Possible Causes
A sticking evaporator fan was observed in this repair, and the fan voltage was reported as 14.7 VDC against a service-manual range of 8–12 VDC. The repairer replaced both the fan and the EBR78940616 control board, after which the problem was corrected. These findings do not establish that the board is the cause in every refrigerator with this symptom; the fan and its circuit need model-specific diagnosis.
What to Check
Check whether the refrigerator compartment is cooling poorly and whether the evaporator fan appears to turn freely, but disconnect power before inspecting internal parts. The reported voltage check was performed in service test mode using model-specific service-manual guidance. Have a qualified technician perform electrical diagnosis and compare readings with the correct manual specifications. Do not replace the board based on the symptom alone.