Samsung range display LEDs or function indicators are inoperative

The range’s LED function indicators do not light or show the selected functions.

Part number: DE96-01050AAppliance brand: SamsungModel: Not specified1 customer repair reports

Common Symptoms

The range’s LED indicators do not show functions. If other parts of the display or controls are also unresponsive, note that when arranging diagnosis.

What to Check

Confirm that the range has power and consult the troubleshooting information for its exact model. If the indicators still do not work, the display control board and its connections may need inspection. The symptom can have more than one cause, so do not assume the board is defective without diagnosis.

When the Control Board May Be Involved

A replacement of the DE96-01050A display control board was followed by working LED function indicators in one repair. That outcome makes the board a possible repair, not a guaranteed cause or fix.

Before Replacing the Board

Match the part to the range’s full model number and verify the part number on the existing board when possible. Disconnect power before inspecting internal components, and use a qualified technician for electrical diagnosis.

Possible Causes

A failed display control board is one possibility; one repair experience reported that replacing the board restored operation. The symptom alone does not confirm a board failure, and other causes have not been ruled out.

What to Check

Confirm that the range has power and note whether the display or other controls respond. Check the range’s model-specific troubleshooting information. If the indicators remain inoperative, have the control board and its connections diagnosed before ordering a replacement. Disconnect power before inspecting internal components; use a qualified technician for electrical diagnosis.

Repair note: These troubleshooting details summarize reported repair experiences. Symptoms can have more than one cause. Disconnect power before inspecting electrical components, and use a qualified technician when a repair involves hazardous voltage or uncertain wiring.