Frigidaire Dishwasher Keeps Filling Even When Off

The dishwasher continues filling when it is switched off, or keeps filling even when the float is raised.

Part number: 5304531745Appliance brand: Frigidaire1 customer repair reports

Common Symptoms

The dishwasher continues filling even when it is off, or does not stop filling when the float is raised. This can create a risk of overflow, so shut off the dishwasher’s water supply if filling continues.

What to Check

Check that the float moves freely and is not obstructed. Mineral buildup or a problem with the water inlet valve may also be relevant. A technician can check the inlet valve and float switch and determine whether the control circuit is keeping the valve energized.

When the Control Board May Be Involved

In one repair, the inlet valve and float switch were checked before the control board was replaced, and the dishwasher worked afterward. The control board, part 5304531745, may be considered if appropriate diagnosis points to it; the symptom alone does not confirm a board failure.

Disconnect power before inspecting internal components. Use a qualified technician for electrical diagnosis.

Possible Causes

A stuck or faulty water inlet valve or float switch can cause continued filling. In one repair, the inlet valve and float switch were checked and the control board was replaced; the dishwasher then worked. That does not confirm the board is the cause in every case.

What to Check

If the dishwasher is still filling, shut off its water supply. Check whether the float moves freely and look for visible mineral buildup around the inlet valve. A qualified technician can assess the valve, float switch, and control circuit. Disconnect power before inspecting internal components.

Repair note: These troubleshooting details summarize reported repair experiences. Symptoms can have more than one cause. Disconnect power before inspecting electrical components, and use a qualified technician when a repair involves hazardous voltage or uncertain wiring.